Stahl - 161887 / 9411/21-210-41

Manufacturer Stahl
Part Number 161887 / 9411/21-210-41
Inner Code 179314
Description ISBus Fieldbus Technology
Custom Code 85363010
Technical specification Field device coupler 8 Spurs for Zone 1 Ex i Application area (zones): 1, 2 Ex interface zone: 0, 1, 2, 20, 21, 22 Terminals: 3-pin (+, -, shield) Max. voltage Uo: 15.7V Max. current IO: 245mA Max. po power: 960mW Min. ambient temperature: -40°C/-40°F Max. ambient temperature: +75°C/+167°F Width: 208.5mm/ 8.21" Height: 83.3mm/3.28" Depth: 128.2 mm/5.05" gas explosion protection II 2 (1) G Ex mb e ib [ia Ga] IIC T4 Gb NI Class I, Div 2 Groups A, B, C, D AIS Class I, II, III, Div 1 Groups A, B, C, D, E, F, G T4 at Ta = 75° C. See Doc. 9411 6 031 001 1
Weight 0.89

Please contact us to request a price quote for Stahl - 161887 / 9411/21-210-41, or for any other model as well. We offer competitive prices, fast delivery and a wide products distribution network in the UK.


WE SELL ONLY NEW AND ORIGINAL PRODUCTS!

Our company is not an authorized distributor. All rights are reserved by the manufacturers and their official partners.

Stahl-161887 / 9411/21-210-41 price

More products of Stahl

  • 150551 / 8570/12-406

    Plug explosion-proof

  • 8570/12-406

    (Plug explosion Proof Type: 8570 / 12-406 Bemessungsbetr.spg. / Frequency: 380-415 V 50/60 Hz Operating current: 16 A Detailed Contacts 4 P (3 P + PE) Color code: red Coding (time position): 6 Housing material: Polyamide Field of Application (zones): 1, 2, 21, 22 Gas explosion protection: II 2 G Ex de IIC T6 Dust explosion protection: II 2 D IP66 80 ° C Ambient temperature min. : -30 ° C Ambient temperature max. +55 ° C Protection (IP): IP66 Terminals: 1.5 mm Cable entry: 8 ... 20 mm plug explosion proof)

  • P/N: 150855, Type: 8571/12-506

    Plug; Explosion-protected

  • 8575/12-100

    PLUG,UTILITY, 2-POLES

  • 151103

    Flange socketexplosion-protectedType : 8575/15-306Rated oper.voltage / Frequency: 200-250 V 50/60 HzRated operational current : 16 ADetailed number of poles : 3 P (2 P + PE)Identification colour : blueCoding (clock hour position) : 6Enclosure material : Polyester resinApplication range (Zone) : 1 , 2Min. ambient temperature : -20 °CMax. ambient temperature : +40 °CType of protection (IP) : IP54

  • p/n: 270900, Type: 8579/31-506

    Switch socket for low temperature, explosion-proof

  • 8602/3

    Pushbutton

  • 8602 STOP

    (Button label Label marking : STOP Colour of label : red For further information, see : www.r-stahl.com Web code 8082A)

  • 8602A0727 1-2-R-V

    (Rotary handle, small lockable explosion-protected Enclosure material : Polyamide Seal : Standard Mounting : with threaded Switching function : latching Number of switching positions : 2 Construction type : vertical Application range (Zone) : 1 , 2 , 21 , 22 Gas explosion protection : II 2 G Ex e II Dust explosion protection : II 2 D Ex tD A21 Min. ambient temperature : -50 °C Max. ambient temperature : +70 °C Type of protection (IP) : IP66 For further information, see : www.r-stahl.com Web code 8082A)

  • 158356

    Max. Voltage Uo : 28 VMax. Current Io : 100 mAMax. Demand Po : 700 mWNumber of channels : 1Polarity : negative polarityApplication range (Zone) : 2Gas explosion protection : II 3 (1) G Ex nA[ia Ga]Dust explosion protection : II (1) D [Ex ia Da] IIICRated operational voltage DC : 24 VMaximum output current Imax : 75 mAFor further information, see : www.r-stahl.com Web code 9001A

  • 9001/01-168-020-101 (158555)

    Single-channel safety barriers explosion-protected

  • 9118/11-11-10 - OBSOLETE (REPLACED BY 9118/11-11-10)

    ics modul-mA isolating repeater(max vol.:8.7 V max. cur.:0.4 mA max. pow.:11mW power supp.:24 vDC)

  • 9160/13-11-11S

    BARRIER: PROTECTIVE, for receiving and transmitting UNIFIED SIGNALs POWER SUPPLY SENSOR, EEX IA IIC

  • 9160/13-11-11S

    (ISpac Isolating Repeater Transmitter Supply Unit Field Circuit Ex i explosion-protected Max. Voltage Uo : 27 V Max. Current Io : 88 mA Max. Demand Po : 576 mW Nominal voltage : 24 V DC Nominal current : 70 mA Power input_W : 1,7 W Number of channels : 1 Input : 0/4 ... 20 mA with HART Output : 0/4 ... 20 mA LFD relay : Yes Min. ambient temperature : -20 °C Max. ambient temperature : +70 °C Application range (Zone) : 2 Gas explosion protection : II 3 (1) G Ex nA nC [ia] IIC T4 Dust explosion protection : II (1) D [Ex iaD])

  • 9164/13-22-08

    mA-Trennübertrager

  • 207909 / 9165/16-11-10s

    iSPAC separation transformer

  • 201270/9165/16-11-11s

    Isolator analog output

  • 9170/10-11-11S

    BARRIER: PROTECTIVE, for receiving and transmitting UNIFIED SIGNALs

  • 9170/10-11-11S

    (ISpac Isolating Repeater Switching Repeater Field Circuit Ex i explosion-protected Max. Voltage Uo : 10,6 V Max. Current Io : 24 mA Max. Demand Po : 64 mW Nominal voltage : 24 V DC Nominal current : 33 mA Number of channels : 1 Output / channel : 2 change over contacts LFD relay : Yes Line fault transparency : No Min. ambient temperature : -20 °C Max. ambient temperature : +70 °C Application range (Zone) : 2 Gas explosion protection : II 3 (1) G Ex nAc nCc [ia] IIC T4 Dust explosion protection : II (1) D [Ex ia] IIIC)

  • 9170/10-12-21s

    (ISpac Switching amplifier Field Circuit Ex i explosion-protected Type : 9170/10-12-21s Max. Voltage Uo : 10,6 V Max. Current Io : 24 mA Max. Demand Po : 64 mW Min. nominal voltage : 120 V Max. nominal voltage : 230 V Nominal current : 12 mA Number of channels : 1 Output / channel : 1 change over contact LFD relay : Yes Line fault transparency : No Min. ambient temperature : -20 °C Max. ambient temperature : +70 °C Gas explosion protection : II (1) G [Ex ia] IIC Dust explosion protection : II (1) D [Ex ia] IIIC)