Stahl - 108212 / EYS2

Manufacturer Stahl
Part Number 108212 / EYS2
Inner Code 5049192
Description Conduit Seal
Custom Code 76090000

Please contact us to request a price quote for Stahl - 108212 / EYS2, or for any other model as well. We offer competitive prices, fast delivery and a wide products distribution network in the UK.


WE SELL ONLY NEW AND ORIGINAL PRODUCTS!

Our company is not an authorized distributor. All rights are reserved by the manufacturers and their official partners.

Stahl-108212 / EYS2 price

More products of Stahl

  • 161887 / 9411/21-210-41

    ISBus Fieldbus Technology

  • 9440/12-01-11(162242)

    Remote I/O IS1CPU and Power Moduleexplosion-protectedType : 9440/12-01-11Version : Profibus DP V0Application range (Zone) : 1Nominal voltage : 24 V DCCurre.consum.(w.8 I/0 modules): approx. 2.5 A at 24 V DCMin. ambient temperature : -20 °CMax. ambient temperature : +65 °CGas explosion protection : II 2 G Exd [ia] [ib] IIC T4 GbCCT No.: 85363010 DENet weigth: 2,653 KG

  • 9440/22-01-11(162227)

    Remote I/O IS1 CPU and Power Module explosion-protected Type : 9440/22-01-11 Version : Profibus DP V0 Application range (Zone) : 1 Nominal voltage : 24 V DC Curre.consum.(w/h I/0 modules): approx. 0.21 A at 24 V DC Curre.consum.(w.8 I/0 modules): approx. 2.5 A at 24 V DC Min. ambient temperature : -20 °C Max. ambient temperature : +65 °C Gas explosion protection : II 2 G Ex d [ia] [ib] IIC T4 Gb CCT No.: 85363010 CN Net weigth: 2,963 KG

  • 9460/12-08-11(168660)

    Remote I/O IS1 Analog Input Module explosion-protected Type : 9460/12-08-11 Version : Ex i Inputs, 8 channels for 2-wire transmitters Application range (Zone) : 1 , 2 , 21 , 22 Ex interface zone : 0 , 1 , 2 , 20 , 21 , 22 Installation in Div. NEC 500 : (Class I) 1/2 & (Class II, III) 1/2 Ex interface in Div. NEC 500 : (Class I) 1/2 & (Class II, III) 1/2 Max. Voltage Uo : 26,2 V Max. Current Io : 86 mA Max. Demand Po : 561 mW Min. ambient temperature : -20 °C Max. ambient temperature : +65 °C Gas explosion protection : II 2 (1) G Ex ib [ia] IIC T4 Dust explosion protection : II (1) D [Ex ia] IIIC CCT No.: 85363010 DE Net weigth: 0,321 KG

  • 9461/12-08-11(168665)

    Remote I/O IS1 Analog Input Module HART explosion-protected Type : 9461/12-08-11 Version : 8 channels for 2-wire HART transmitters Application range (Zone) : 1 , 2 , 21 , 22 Max. Voltage Uo : 1 V Max. Demand Po : 591 mW Min. ambient temperature : -20 °C Max. ambient temperature : +65 °C Gas explosion protection : II 2 (1) G Ex ib [ia] IIC T4 Dust explosion protection : II (1) D [Ex ia] IIIC CCT No.: 85363010 Net weigth: 0,400 KG

  • 9466/12-08-11

    Remote I/O IS1+ Analog Output Module HART explosion-protected

  • 9470/22-16-11(168682)

    Remote I/O IS1 Digital Input Module explosion-protected Type : 9470/22-16-11 Version : 16 channels Application range (Zone) : 1 , 2 , 21 , 22 Max. Voltage Uo : 11,6 V Max. Current Io : 22 mA Max. Demand Po : 51 mW Min. ambient temperature : -20 °C Max. ambient temperature : +65 °C Gas explosion protection : II 2 (1) G Ex ib [ia] IIC T4 Dust explosion protection : II (1) D [Ex ia] IIIC CCT No.: 85363010 DE Net weigth: 0,316 KG

  • 168734 / 9475/12-04-21

    Remote I/O IS1Digital Output Moduleexplosion-protectedType : 9475/12-04-21Version : 4 channelsApplication range (Zone) : 1 , 2 , 21 , 22Max. Voltage Uo (Ex ia) : 26,2 VMax. Voltage Uo (Ex ib) : 26,2 VMax. Current Io (Ex ia) : 110 mAMax. Current Io (Ex ib) : 60 mAMax. Demand Po (Ex ia) : 722 mWMax. Demand Po (Ex ib) : 722 mWMin. ambient temperature : -20 °CMax. ambient temperature : +65 °CCCT No.: 85363010 CNNet weigth: 0,275 KG

  • 9475/12-08-51(168687)

    Remote I/O IS1 Digital Output Module explosion-protected Type : 9475/12-08-51 Version : 8 channels Application range (Zone) : 1 , 2 , 21 , 22 Max. Voltage Uo (Ex ia) : 19,9 V Max. Voltage Uo (Ex ib) : 19,9 V Max. Current Io (Ex ia) : 145 mA Max. Current Io (Ex ib) : 38 mA Max. Demand Po (Ex ia) : 719 mW Max. Demand Po (Ex ib) : 558 mW Min. ambient temperature : -20 °C Max. ambient temperature : +65 °C Gas explosion protection : II 2 (1) G EEx ib [ia] IIC/IIB T4 Dust explosion protection : II (1/2) D [Ex iaD/ibD] CCT No.: 85363010 CN Net weigth: 0,275 KG

  • 9475/12-08-61

    Remote I/O IS1+ Digital Output Module explosion-protected

  • 9475/12-08-61(168688)

    Remote I/O IS1 Digital Output Module explosion-protected Type : 9475/12-08-61 Version : 8 channels Application range (Zone) : 1 , 2 , 21 , 22 Max. Voltage Uo (Ex ia) : 26,2 V Max. Voltage Uo (Ex ib) : 26,2 V Max. Current Io (Ex ia) : 107 mA Max. Current Io (Ex ib) : 30 mA Max. Demand Po (Ex ia) : 697 mW Max. Demand Po (Ex ib) : 565 mW Min. ambient temperature : -20 °C Max. ambient temperature : +65 °C Gas explosion protection : II 2 (1) G EEx ib [ia] IIC/IIB T4 Dust explosion protection : II (1/2) D [Ex iaD/ibD] CCT No.: 85363010 CN Net weigth: 0,275 KG

  • 9475/22-08-51

    I.S.1 8DO MODULE

  • 9477/12-08-12(162627)

    Remote I/O IS1 Digital Output Module Relay explosion-protected Type : 9477/12-08-12 Version : 8 contacts Application range (Zone) : 1 , 2 Maximum switching voltage : 60 V AC Maximum switching current : 2 A Min. ambient temperature : -20 °C Max. ambient temperature : +65 °C Gas explosion protection : II 2 G Ex d e [ia, ib] IIC T4 CCT No.: 85363010 DE Net weigth: 2,570 KG

  • 9477/15-08-12(168694)

    Remote I/O IS1 Digital Output Module Relay explosion-protected Type : 9477/15-08-12 Maximum switching voltage : 250 V AC Maximum switching current : 2 A Min. ambient temperature : -20 °C Max. ambient temperature : +65 °C Gas explosion protection : II 3 (2) G Ex nAc nCc nLc [ib] IIC T4 CCT No.: 85363010 DE