ProMinent - PHWS014

Manufacturer ProMinent
Part Number PHWS014
Inner Code 3344671
Technical specification Serial No: 511822 DULCOMETER Ph Meter / 220V , 50Hz.
Weight 1

Please contact us to request a price quote for ProMinent - PHWS014 , or for any other model as well. We offer competitive prices, fast delivery and a wide products distribution network in the UK.


WE SELL ONLY NEW AND ORIGINAL PRODUCTS!

Our company is not an authorized distributor. All rights are reserved by the manufacturers and their official partners.

ProMinent-PHWS014     price

More products of ProMinent

  • CLE 3-MA-0.5PPM

    Chlorine sensor Amperometric two-electrode cell with diaphragm cap, flow-independent, stable zero point, integr. Temperature compensation. Typical applications: drinking water, dechlorination Terminal / diameter: mm 2-pol./25 Measuring range: 0,01..0,5 mg / liter Parameter: free chlorine pH range: 5,5..8,0 temperature / pressure: 5..45 degrees C / 1 bar Flow: 30..60 L / h Installation length: 221 mm Order number: 792927

  • CON1312

    Conductivity sensor DE01, DE02, HY01, HY02, TCS

  • D1CAD0C10001G2100E

    Chlorine Analyzer (Dulcometer) Power Supply 230VAC/0.05A

  • D1CBW00601000VD1201G00EN

    Controller DULCOMETER D1Cb Identcode: D1CBW00601000VD1201G00EN Series: D1Cb D1Cb DULCOMETER Mounting: W wall mounting IP65 Design: 00 + LCD keyboard, with PM Logo Operating voltage: 6 90-253 VAC 50/60 Hz Approvals: 01 CE mark Hardware extension: 0 No Hardware extension: 0 No External connection: 0 No Software preset: preset V software Preset Meas: D chlorine dioxide Terminal of the Meßgröß: 1 mA Correction quantity: 2 Temp.Pt100 via terminal (pH, conductivity) Control input: 0 No (default) Signal output: 1 1 analogue signal output 0 / 4-20mA Power activation G Alarm + 2 limit values ​​(Standard) Pump control: 0 Without (standard) Control behavior: 0 No (default) Default speech bubble: EN English (British) Frequency: 50/60 HZ Voltage: 90-253 VAC Power: 12 W ~ Protection: IP65

  • DHV-RM REPLACED BY > DHV-U DN25 PVT

    VALVE, RLF, THD, 1.5 ", PROMNT, DHVRM, 1000056

  • DHV-U DN25 PVT

    Pressure-sustaining valve

  • DLTA0280PVT2000UA0030EN0

    (Series: DLTA Delta Optodrive- version A, pump type: 02bar 0280, 75 l / h conn.DN10)

  • DLTA0280PVT2010UA1130EN0

    delta -optodrive ProMinent delta(R) Magnet-Membrandosierpumpe

  • DLTA0450PVT2000UA1130EN0

    Series: DLTA Delta Optodrive- Version A Pump type: 04bar 0450, 49 l / h conn.DN10 Dosing head: PV PVDF Seal material: T Standardmembr. / PTFE sealing. Dosing head: 2 m.Entlüftung, o.Ventilfeder Hydraulic Conn: 0 standard connection Diaphragm failure monitor: 0 None Version: 0 With PM-Logo Execution performance: U universal controller 100 - 240 V Cables and connectors: A 2m Europe Relay function: 1 alarm sloping Accessories: 1 Dos.v. 1/2 "and Fußv. Control variant: 3 Manual + analog current PC + Security Options: 0 no access control Language: English EN Remote Stop: 0 Pause break contact, level Opener Admission: 01 CE Frequency: 50-60Hz Voltage: 100-240V Power: 73W Protection: IP65 Capacity: 49,0l / h Back pressure: 04bar

  • DLTA1020PVT3000UA00M0DE0

    Series: DLTA Delta Optodrive- Version A Pump Type: 1020 10bar, 19,1l / h con.12x9 / SS12x10 Dosing head: PV PVDF Seal material: T Standardmembr. / PTFE sealing. Dosing head: 3 m.Entlüftung, m.Ventilfeder Hydraulic Conn: 0 standard connection Diaphragm failure monitor: 0 None Version: 0 With PM-Logo Execution performance: U universal controller 100 - 240 V Cables and connectors: A 2m Europe Relay function: 0 without relay Accessories: 0 without accessories Control variant: M control module 4 -20 mA Security Options: 0 no access control Language: DE German Remote Stop: 0 Pause break contact, level Opener Admission: 01 CE Frequency: 50-60Hz Voltage: 100-240V Power: 73W Protection: IP65 Capacity: 19,1l / h Back pressure: 10bar

  • DLTA1612SST0000UA3030EN0

    Series: DLTA Delta Optodrive- Version A Pump Type: 1612 16bar, 11,3l / h conn.8x5 / SS8x7 Dosing head: SS stainless steel Seal material: T Standardmembr. / PTFE sealing. Dosing head: 0 o.Entlüftung, o.Ventilfeder Hydraulic Conn: 0 standard connection Diaphragm failure monitor: 0 None Version: 0 With PM-Logo Execution performance: U universal controller 100 - 240 V Cables and connectors: A 2m Europe Relay function: 3 Fail safe appealing Accessories: 0 without accessories Control variant: 3 Manual + analog current PC + Security Options: 0 no access control Language: English EN Remote Stop: 0 Pause break contact, level Opener Admission: 01 CE Frequency: 50-60Hz Voltage: 100-240V Power: 73W Protection: IP65 Capacity: 11,3l / h Back pressure: 16bar

  • DN6 PN400 1.4462

    Plug valve Order number: 1018190

  • 1023175

    dosing container

  • DULCOMETER D1CB W00601000

    type: D1C b Mounting: Wall version Power supply: 220 V, 50/60 Hz; IP 65 Dimensions (WxHxD): 200x200x76 mm

  • DUODOS 10 PVDF-E

    air driven double diaphragm pump

  • DUODOS 10 PVDF-E

    Order number: 1010797

  • GALA0420TTT000UA100000 GALA GAMMA/L- PUMPE VERSION A

    Pump type: 0420 4 bar, 20 l / h St.Anschl.12x9 Dosing head: TT PTFE + 25% carbon Seal material: T standard Membr./ PTFE sealing. Dosing head: 0 o.Entlüftung, o.Ventilfeder Hydraulic Conn: 0 standard connection Version: 0 With PM-Logo Execution performance: U universal controller 100 - 240 V Cables and connectors: A 2m Europe Relay function: 1 alarm sloping Accessories: 0 without accessories Control variant: 0 Manual + Cont. 1: 1 Security Options: 0 no access control Dosing monitoring: 0 dosing monitor dynamically Remote Stop: 0 Pause break contact, level Opener Admission: 01 CE Frequency: 50 / 60Hz Voltage: 100-230V Power: 23W Protection: IP65 Capacity: 17,1l / h Back pressure: 04bar

Other Category Brands