Manufacturer ProMinent
Part Number 1010380
Inner Code 4305416
Custom Code 84818081
Technical specification Laboratory ball valve d10 DN6 1/4 “PVC without Name: 2-way ball valve Design: 3-piece, lockable Nominal size: DN8 - G 1/4" (ISO 228) Nominal pressure: PN10 Product affected material: PVC-U Seal material: FPM Connection 1: threaded sleeve G 1/4" (ISO 228) Connection 2: threaded connector G 1/4" (ISO 228) Connector 3: without Drive: manual drive Drive function: manually operated on/off Voltage: without Admission: without accessories: without Special feature: without

Please contact us to request a price quote for ProMinent - 1010380, or for any other model as well. We offer competitive prices, fast delivery and a wide products distribution network in the UK.


WE SELL ONLY NEW AND ORIGINAL PRODUCTS!

Our company is not an authorized distributor. All rights are reserved by the manufacturers and their official partners.

ProMinent-1010380 price

More products of ProMinent

  • BETA 5B NO:BT5B0232PVT0000UA000000

    Series: BT5B BETA 5 - pump Version B Pump Type: 0232 02bar, 32l / h Ansch.12x9 / SS12x10 Dosing head: PV PVDF Seal material: T standard Membr. m.PTFE sealing. Dosing head: 0 o.Entlüftung, o.Ventilfeder Hydraulic Conn: 0 standard connection Format: 0 Geh.RAL5003 / hood RAL2003 Logo: 0 with PM-Logo Voltage version: U Universal 100-240 V Cables and connectors: A 2m Europe Relay function: 0 without relay Accessories: 0 without accessories Control Type: 0 no lock Control variant: 0 Pulse Control Remote Stop: 0 Pause break contact, Niv opener. Auxiliary: 0 = external frequency 180max Admission: 01 CE Frequency (Hz): 50 / 60Hz Voltage (V): 100-230V Power (W): 24,9W Protection: IP65 Flow rate: 32l / h Back pressure: 02bar

  • BT4B0413PPT2300UA400000

    Series: BT4b BETA 4 - pump Version B Pump Type: 0413 04bar, 13l / h Anschl.8x5 / SS8x7 Dosing head: PP polypropylene Seal material: T standard Membr. m.PTFE sealing. Dosing head: 2 m.Entlüftung, o.Ventilfeder Hydraulic Conn: 3 Special connection 12x9 Format: 0 Geh.RAL5003 / hood RAL2003 Logo: 0 with PM-Logo Voltage version: U Universal 100-240 V Cables and connectors: A 2m Europe Relay function: 4 Störm.rel. abf. + Taktg. Disp. Accessories: 0 without accessories Control Type: 0 no lock Control variant: 0 Pulse Control Remote Stop: 0 Pause break contact, Niv opener. Auxiliary: 0 = external frequency 180max Admission: 01 CE Frequency (Hz): 50 / 60Hz Voltage (V): 100-230V Power (W): 16.5W Protection: IP65 Capacity: 12,3l / h Back pressure: 04bar

  • BT4B0413PPT2300UA400000

    Series: BT4b BETA 4 - pump Version B Pump Type: 0413 04bar, 13l / h Anschl.8x5 / SS8x7 Dosing head: PP polypropylene Seal material: T standard Membr. m.PTFE sealing. Dosing head: 2 m.Entlüftung, o.Ventilfeder Hydraulic Conn: 3 Special connection 12x9 Format: 0 Geh.RAL5003 / hood RAL2003 Logo: 0 with PM-Logo Voltage version: U Universal 100-240 V Cables and connectors: A 2m Europe Relay function: 4 Störm.rel. abf. + Taktg. Disp. Accessories: 0 without accessories Control Type: 0 no lock Control variant: 0 Pulse Control Remote Stop: 0 Pause break contact, Niv opener. Auxiliary: 0 = external frequency 180max Admission: 01 CE Frequency (Hz): 50 / 60Hz Voltage (V): 100-230V Power (W): 16.5W Protection: IP65 Capacity: 12,3l / h Back pressure: 04bar

  • BT4B Magnetdosierpumpe beta 4b

    Identcode: BT4B0708PVT2000UA100000 Series: BT4b BETA 4 - pump Version B Pump Type: 0708 07bar, 8l / h Anschl.8x5 / SS8x7 Dosing head: PV PVDF Seal material: T standard Membr. m.PTFE sealing. Dosing head: 2 m.Entlüftung, o.Ventilfeder Hydraulic Conn: 0 standard connection Format: 0 Geh.RAL5003 / hood RAL2003 Logo: 0 with PM-Logo Voltage version: U Universal 100-240 V Cables and connectors: A 2m Europe Relay function: 1 alarm sloping Accessories: 0 without accessories Control Type: 0 no lock Control variant: 0 Pulse Control Remote Stop: 0 Pause break contact, Niv opener. Auxiliary: 0 = external frequency 180max Admission: 01 CE Frequency (Hz): 50 / 60Hz Voltage (V): 100-230V Power (W): 16.5W Protection: IP65 Capacity: 7,1l / h Back pressure: 07bar

  • BT4B1004PPB2000UA010000

    Series: BT4b BETA 4 - pump Version B Pump Type: 1004 10bar, 4l / h Anschl.6x4 / SS6x5 Dosing head: PP polypropylene Seal material: B Standard Membr. m.FPM-B seal. Dosing head: 2 m.Entlüftung, o.Ventilfeder Hydraulic Conn: 0 standard connection Format: 0 Geh.RAL5003 / hood RAL2003 Logo: 0 with PM-Logo Voltage version: U Universal 100-240 V Cables and connectors: A 2m Europe Relay function: 0 without relay Accessories:. 1 Dos.v.u.Fußv, 2mSchl.5mPE Schl Control Type: 0 no lock Control variant: 0 Pulse Control Remote Stop: 0 Pause break contact, Niv opener. Auxiliary: 0 = external frequency 180max Admission: 01 CE Frequency (Hz): 50 / 60Hz Voltage (V): 100-230V Power (W): 12,7W Protection: IP65 Capacity: 3,9l / h Back pressure: 10bar

  • BT4B1602PPB2000UA010000

    Dosierpumpe BT4b kpl.

  • BT4B1602PPB2000UA010000

    Magnetdosierpumpe beta 4b

  • BT4B1602PPE2000UA100000

    Metering BT4b kpl

  • BT4B1602PPT2000UA010000

    Beta 4b magnetic dosing pump

  • BT5B0232PPE0000UA000000

    Solenoid metering pump beta 5b

  • BT5B0232PVT0000UA000000

    (Series: BT5B BETA 5 - pump Version B Pump Type: 0232 02bar, 32l / h Ansch.12x9 / SS12x10 Dosing head: PV PVDF Seal material: T standard Membr. m.PTFE sealing. Dosing head: 0 o.Entlüftung, o.Ventilfeder Hydraulic Conn: 0 standard connection Format: 0 Geh.RAL5003 / hood RAL2003 Logo: 0 with PM-Logo Voltage version: U Universal 100-240 V Cables and connectors: A 2m Europe Relay function: 0 without relay Accessories: 0 without accessories)

  • BT5B0232TTT0000UB400000

    BT5B BETA 5 - pump Version B

  • BT5B0713PPB2000UA010000

    Series: BT5B BETA 5 - pump Version B Pump type: 0713 07 bar, 13l / h Anschl.8x5 / SS8x7 Dosing head: PP polypropylene Seal material: B Standard Membr. m.FPM-B seal. Dosing head: 2 m.Entlüftung, o.Ventilfeder Hydraulic Conn: 0 standard connection Format: 0 Geh.RAL5003 / hood RAL2003 Logo: 0 with PM-Logo Voltage version: U Universal 100-240 V Cables and connectors: A 2m Europe Relay function: 0 without relay Accessories:. 1 Dos.v.u.Fußv, 2mSchl.5mPE Schl Control Type: 0 no lock Control variant: 0 Pulse Control Remote Stop: 0 Pause break contact, Niv opener. Auxiliary: 0 = external frequency 180max Admission: 01 CE Frequency (Hz): 50 / 60Hz Voltage (V): 100-230V Power (W): 21,2W Protection: IP65 Capacity: 11,0l / h Back pressure: 07bar

  • BT5B0713PVT200UA

    DOSING PUMP

  • BT5B1008PVT2000UA000000

    magnetic metering pump

  • CDE 2-MA-2 PPM

    ClO2 measuring cell connection / Diameter: 2-pol./25 mm Measuring range: 0,02..2 mg / liter Parameter: chlorine dioxide pH range: 5,5..9,5 Temperature / Pressure: 5..45 degrees C / 3 bar Flow: 30..60 L / h Installation length: 221 mm Order number: 792929

  • CLE 3-MA-0.5PPM

    Chlorine sensor Amperometric two-electrode cell with diaphragm cap, flow-independent, stable zero point, integr. Temperature compensation. Typical applications: drinking water, dechlorination Terminal / diameter: mm 2-pol./25 Measuring range: 0,01..0,5 mg / liter Parameter: free chlorine pH range: 5,5..8,0 temperature / pressure: 5..45 degrees C / 1 bar Flow: 30..60 L / h Installation length: 221 mm Order number: 792927

  • CON1312

    Conductivity sensor DE01, DE02, HY01, HY02, TCS