Siemens (Landis Gyr) - MVL661.15-1.0

Manufacturer Siemens (Landis Gyr)
Part Number MVL661.15-1.0
Inner Code 783243
Description Cold Valve
Custom Code 84818059
Technical specification for expansion, hot gas and suction choke appliques Operating voltage: AC 24 V, DC 20... 30 V Power consumption: 22 VA Set signal: DC 0/2... 10V; 0/4... 20mA Emergency function: control path closed pergil. Operating pressure: 4000kPa Nominal diameter: DN15 kvs: 1,0 m³/h Medium temperature ፦40... 120°C Degree of protection: IP65 Ambient temperature ፦25... 55°C Dimensions: approx. 150 x 103 x 279 mm (L x W x H) Weight: approx. 4.40 kg Country of origin: Germany Stat. Warenr.: 84818059 AL: N ECCN: N
Weight 4.4

Please contact us to request a price quote for Siemens (Landis Gyr) - MVL661.15-1.0, or for any other model as well. We offer competitive prices, fast delivery and a wide products distribution network in the UK.


WE SELL ONLY NEW AND ORIGINAL PRODUCTS!

Our company is not an authorized distributor. All rights are reserved by the manufacturers and their official partners.

Siemens (Landis Gyr)-MVL661.15-1.0 price

More products of Siemens (Landis Gyr)

  • ASZ16,703,1350HM

    PAW TION METER

  • CODE NO: 3003536 DRAWING NO: TCK950

    Thermocouple for exhaust gas temperature Thermocouple – K, Max Temperature - 950°C

  • deleted

    for Robot

  • KF8852

    Adpter for L17 -> LGB21, LMG21

  • L00024

    Adapter AGA60 for SAX ... on gas valves VG ../ VL .. Dimensions: about 80 x 80 x 85 (L x B x H in mm) Weight: 0.40 kg Country of origin: Germany / Stat. W.-. Reference: 84169000, Al: N ECCN: N

  • L00024 AGA60

    Adapter AGA60, for SAX on gas valves VG / VL Mass 80x80x85 (Lx B x H in mm) Weight 0.32 kg

  • L00093

    UV replacement cell AGR4 502 1131 0 for QRA2, QRA2.9, QRA10 Dimensions: approx. 35 x 20 x 20 (L x B x H in mm) Weight: 0.01 kg Country of origin: Germany / Stat. W. No .: 84159000 AL: N ECCN: N

  • L00094 AGR4 502 4065 0

    UV für QRA2M, QRA10M, QRA% (outer QRA50M), QRA65 DIMENSIONS 35x20x20 mm Weight 0,01 kg Customs tariff number 84169000

  • L00094 UV-ERSATZZELLE AGR4 502 4065 0

    for QRA2M, QRA10M, QRA5 ... (except QRA50M) QRA65 Dimensions: 35 x 20 x 20 (L x B x H in mm) Weight: 0.01kg Country of origin: Germany / Stat. W. No .: 84169000

  • L00184

    Flame detector LFE10

  • L00184 LFE10

    (Flame monitor for intermittent operation, for oil and gas burners to LEC 1 ... Flame supervision with flame detector Power supply: AC220 V - 15% ... 240 V + 10% Frequency: 50 Hz ... 60 Hz +/- 6% Power consumption: 4.5 VA Temperature range: -20 ... + 60 ° C Humidity: <95% RH Protection: IP40 (make by installing) Mass: ca. 85 x 62 x 90 (L x B x H in mm) Weight: 0.40 kg Urprungsland: Germany / Stat. W. -Nr.:84169000 AL: N ECCN: N)

  • L00196

    Gas-Oil Burner, LFL1.635 for intermittent operation, Prepurge (tl): 66s 1.Sicherheitszeit (TSA): 2.5s 2.Sicherheitszeit (t9): 5s Factory setting of times for 50 Hz power frequency Power supply: AC230 V -15% / + 10% Frequency: 50 ... 60 Hz +/- 6% Power consumption: 3.5 VA Temperature range: -20 ... + 60 ° C Humidity: <95% RH Protection: IP40 (make by Einbauch) Dimensions: approx 1.02 kg Country of origin: Germany / Stat. W. No .: 84169000 AL: N ECCN: N

  • L00260

    photocell

  • L00260

    UV sensor Flammer QRA10.C for LGB .... with AGQ1 ..., LFL ...., LFE1 ... LMG ... with AGQ2 ... LME ... with AGQ3 ... (except LME1 ...), LMV ... (LMV5 with AGQ1 ...) for monitoring gas flames, yellow or blue burning oil flames and for ignition spark sensitivity. normal, permissible combustion chamber pressure: max. 50 mbar, Temperature Range: <98% R.F., Schuztart: IP54 (IP65 with AGG08), dimensions: approximately 87 x 65 x 120 (L x W x H in mm) Weight: 0.78 kg

  • L00262 UV - FLAMMENFUHLER QR

    UV - flame detector QR for LGB..mit AGQ1..LFL..LFE1..LMG..mit AGQ2..LME..mit AGQ3 .. (except LME1) .. .. LMV (LMV5..mit AGQ1 ..) for monitoring gas flame, yellow or blue brenenden oil flames and for ignition spark Sensitivity: normal Cable entry: 2 x 0.75 mm²; Dia. 5,1mm Temperature range: -20 ... + 60 ° C Humidity: <95% RH Protection: IP40 Dimensions: approx 0.03 kg Country of origin: Germany / Stat. W. No .: 84169000 AL: N ECCN: N

  • L00267

    photocell

  • L00347

    Actuator SQM20.18502 for gas and air valves, Rotation: left Rated torque: 12Nm Drive shaft: 12mm round, hardened Run time: 45s / 90 °, 66s / 130 ° setting angle: up to 160 ° Limit: 2 Auxiliary: 5 wiring: according to Scheme 1 Power supply voltage: AC220 ... 240 V -15% / + 10% Frequency: 50 Hz - 15% / + 10% Power consumption: 9 VA Protection: IP54 according to DIN 40050 Temperature range: -20 ... + 60 ° C Humidity: <95% R.F. Cable entry: 2 x M16 x 1,5 / 2 x M20 x 1.5 Dimensions: 120 x 120 x 190 (L x W x H in mm) Weight: ca.1,86 kg Country of origin: Germany / Stat. W.- No .: 84169000 AL: N ECCN: EAR99

  • L00548, SKD32.50

    for through and three-way valves VV ... VX überlastischer, slot for 1x auxiliary switch or 1x Potentiometerm with manual adjustment, Operating voltage AC 230 V Control signal 3-point Setting time 120 s Force 1000N hub 20mm

  • L00834 AGG5.220-220V

    source transformer for Can BUS user, especially on the LMV5 ... customized performance Dimensions. about 120 x 90 x 80 (LxWxH in mm) Weight about 2.40 kg Country of origin de- instead. W is NR. 85043180 Al: N ECCN: N

  • LAL1 .25

    Oil Burner

  • LAL2.25

    Oil burner control

  • LAL2,25

    Oil Burner Siemens

  • LAL3.25

    Olfeuerungsautomat

Other Category Brands