ARDETEM - 20223 DIP40 0A1 R

Manufacturer ARDETEM
Part Number 20223 DIP40 0A1 R
Inner Code 65949
Description Display with bi-directional Process input, analog output + 2 relays Digital display 48 x 96mm, 4 digits bidirectional process input (mA, mV, V) mA output active and 2 relays Universal power supply 24 - 240VAC / DC via front panel or by means of PC and software SUPERVISION
Technical specification -Accuracy 0,1% of the full scale at +25 C Thermic drift <150 ppm/C -Measurable scale overstepping from -10% to +10% -Scale factor programmable -Enlarging effect-Square root extraction -Special linearisation on 20 points -Supply for 2 or 3 wire sensor 24 Vdc -25 mA protected from short circuits
Weight 1

Please contact us to request a price quote for ARDETEM - 20223 DIP40 0A1 R, or for any other model as well. We offer competitive prices, fast delivery and a wide products distribution network in the UK.


WE SELL ONLY NEW AND ORIGINAL PRODUCTS!

Our company is not an authorized distributor. All rights are reserved by the manufacturers and their official partners.

ARDETEM-20223  DIP40 0A1 R price

More products of ARDETEM

  • 20008

    DRB-5 TPI DIN rail holder Connecting terminal / connector for Hat rail for the power supply and bus for two devices, a connector is required

  • 20064 PECA11D2RF

    Three-phase universal analyzer Disturbancen Three-phase universal analyzer interference 3 or 4 wire three-phase systems, reading out balanced and unbalanced networks 2 R-2 relay outputs NO F - Modbus TCP Ethernet output Display: 96 x 96 backlit Display up to 50 parameters Upper and lower wave analysis 2 programmable voltage ranges Un = 100V LN / 173V LL and 330V LN / 600V LL 2 programmable current areas A 0..1 and 0..5 A Universal power supply AC / DC Reaction time 40 ms (2 cycles) Standard output RS 485 Modbus Customs tariff number: 9030390090 Country of origin: France / EU

  • 20085

    TPIs 50 N F / I converter Ethernet single-channel frequency converter Input: contact, logic, Namur, NPN / PNP Analog output: 0 - 20 mA, 0 - 10 V PC programmable with software SUPERVISION via USB port or Ethernet

  • 20090

    TPIs 12 transmitters with process input 1 analog output Transmitters with process input in 7.2 mm-housing Input: mA; mV; V 1 Analog output: 0 - 10 V; 0/4 - 20 mA active Power: 24 VDC PC programmable with software SUPERVISION via USB port

  • 20164 PECA11D2RF

    Universal phase analyzer Disturbancen AC universal analyzer for interference 3 or 4 wire three-phase systems, reading balanced and unbalanced networks 2 R-2 relay outputs NO F - Modbus TCP Ethernet output Display: 96 x 96 with backlight Display up to 50 parameters Upper and lower wave analysis 2 programmable voltage ranges Un = 100V LN / LN 173V LL and 330V / 600V LL 2 programmable current ranges 0 to 1 A and 0 .5 A Universal Power Supply AC / DC 40ms response time (2 periods) Standard output RS 485 Modbus Customs tariff number: 9030390090 Country of origin: France / EU

  • 20182 TRM4 2A

    TRM4 2A Universal three-phase analyzerUniversal three-phase analyzer3 or 4 wire three-phase systems, readingbalanced and unbalanced networksInput: Voltage 0 3 .150 VAC, 0 ... 500 VACOutput: 3 Current 0 .1 0 .5 A and A (automaticswitching)Universal power supply AC / DCResponse time 40ms (two periods)Outputs 2 x analog bipolar)PC programmable with software SUPERVISIONPossible options:Up to 5 programmable analog0 ... 20mA, 4 ... 20mA, 0 ... 5 mA two of thesebipolar)4 output relays without analog output, or 2Relay outputs with max. 2 analog outputsEthernetProfibus DP• Overload: 10 times the rated current for 10 seconds• 50 times rated current (EDF standard) for 60 ms

  • 20223 DIP400 A1 R

    Display with bidirectional process input

  • 20224 DIP402 R

    Display 48 x 96mm with Universal Input + 2 relays in the output Digital display 48 x 96mm, 4 digits Universal input mA, V, temp. Potentiometer resistance 2 relays in the output Universal power supply 24 - 240VAC / DC via front panel or by means of PC and software SUPERVISION

  • 20224 DIP402 R

    Display with 48 x 96mm Universal input + 2 output relays in Digital display 48 x 96mm, 4 digits Universal input mA, V, temp potentiometers, resistance 2 relay output in Universal power supply 24 - 240VAC/DC Programmable via front keys or with PC and software SUPERVISION

  • ART.NR. 20009

    Supervision programming tool Software to program the ARDETEM Devices including USB interface and connection cables

  • ART.NR. 20012

    μCONSOLE LCD Display / Removable programming unit for all Ardetem devices

  • ART.NR. 20017

    TPI 10 AR universal transmitter with Analog output and 2 relays TPI 10 AR Universal Input: current, voltage, temperature resistance Output: Analog (current / voltage), 2 relays Programmable with display / PC Universal power supply: 20-300 VDC / VAC

  • DIP400 with tropicalization option.

    digital indicator universal power supply

  • PECA 30 ES 5 A2

    electrical network analyzer

  • PECA11

    ELECTRICAL MEASURE CENTRAL Current input: 1A and 5 A AC Voltage input: 175 V and 600 V AC For all network types Graphical LCD with rear-lighting 28 measurable parameters: 3U, 3V, 3I, cos, f, F, P, Q, S, E... Display of the energies on 8 digits on a single line with automatic switching to the upper unit Automatic correction of the wiring Output: RS 485 Modbus/Jbus Universal power supply; 20 to 270 vac and 20 to 300 vdc Format: 96x96mm

  • PECA11 DC 15-50

    Measurement of DC signals - Dimensions 96x96x108mm -LCD ,DC networks

  • PECA3001

    Signal analyzer for electrical networks

  • SP125 ARD

    INSULATION FAULT DETECTOR

  • TAI 60

    programmable transmitter

  • TMA-HI

    AC MEASURE TRANSMITTERS - high insulation 4KV. Input 0-5A and standard output 4-20mA Galvanic partition: 4Kv Accuracy rating: <0.3% Power supply: 20 to 270 Vac and 20 to 300 Vdc

  • TMP

    DC MEASURE TRANSDUCER / DC CONVERTER Input / input: 0-1000 VDC Output / output: 4-20 mA Galvanic partition / galvanic isolation: 2KV Accuracy rating / accuracy: 0.2% For DIN rail mounting / for DIN rail mounting Power supply / power supply: 20 ... 270 Vac and 20 ... 300 Vdc

  • TMP-HI-2

    TMP-HI-2 EXCITATION CURRENT TRANSDUCER ,I/P : 75A/100mV O/P : 4-20 mA AUX : 90-270 VAC, 88-350 VDC 2-WIRE SENSOR

  • TMvP-HI-3-SP12/05

    Universal current and voltage transmitter

  • TPI400 A

    PROGRAMMABLE CONVERTER Input: mA,mV,V. Bidirectionnal current and voltage input up to +/- 300 V dc Accuracy rating: 0.1% Programmable scale factor Supply for 2-wire sensor Insulated analog output (voltage or current) For DIN rail mounting Programmable by software or µconsole (optional) Universal power supply: 20 to 270 vac and 20 to 300 vdc

  • TRM 2

    A three-phase analyzer for synchronous networks Three-phase analyzer for synchronous networks DIN-rail mounting AC indicator for exchange or Three-phase systems Voltage input 0 1 .150 VAC, 0 ... 600 VAC + 20% 1 Current input 0 .1 0 .5 A or A (automatic switching) Spanungsversorgung Universal AC / DC Response time 40ms (two periods) 1 analogue output Programmable with Display (LCD μCONSOLE) or PC

Other Category Brands